If your submersible sewage pump keeps clogging, the clog is rarely the real problem. It is a sign. Something about the sewage, the pump or the pit does not match, and the pump pays for it again and again.
This guide covers the common causes, a step-by-step way to troubleshoot, and ways to stop repeat blockages. It also explains what to look for in a non-clog pump.
Short answer: Most clogs come from five causes: rags and wipes, oversized solids, grease, sediment, or a poor pump match. Find which one you have before you clean the pump again.
What Happens When a Sewage Pump Starts Clogging?
A clogged impeller cannot move liquid. Flow drops and the motor works harder. Heat and vibration rise. If you leave it, seals, bearings and the motor take damage. The pit fills, and in the worst case sewage backs up.
Each clog also costs downtime, labour and maintenance costs. Repeated clogs shorten pump life.
Common Signs of a Clogged Sewage Pump
- Flow drops, or the pit empties slowly
- The pump runs longer or cycles more often
- The motor trips on overload or runs hot
- New vibration or noise
- A high-level alarm or sewage backup
A rise in motor current can be an early warning, before any of the signs above.
What Usually Causes a Submersible Sewage Pump to Clog?
Most repeat clogs trace back to five causes. Often two or three act together.
1. Rags, Wipes and Long Fibrous Materials
Wipes, rags, hair and plastic strands do not break down in sewage. They wrap around the impeller and build into a rope of long fibers that grows with every pass. Wipes sold as flushable often fail to break down in real sewers. Wastewater utilities report that they clog pumps and screens across municipal sewer systems, as this NACWA fact sheet on wipes explains. Even a wide-passage pump can rag up this way.
2. Large Solids That Exceed the Pump’s Free Passage
Every pump has a maximum solid size it can pass. Anything above that size jams in the casing. Stones, plastic sheets and construction debris are common examples. Compare the free passage on the datasheet with the biggest solid on your site, not the average one.
3. Grease, Oil and Buildup Inside the Pump
Fat, oil and grease cool in the pit and stick to walls, floats and the impeller. They bind with fibers into a hard mat. Kitchens, food plants and some industrial sewage add the most grease.
4. Sediment, Grit and Mineral Scale
Sand and grit settle in the sump when flow is low. The pump then draws up heavy sludge. Hard water and mineral-rich effluent leave scale. Scale narrows passages and gives fibers a rough surface to catch on.
5. Pump Selection, Installation or Operating Conditions
Some clogs come from the match, not the sewage. Watch for these:
- An impeller type that does not suit fibrous sewage
- An oversized pump running at low flow, so solids settle
- A pump sitting in sludge on the pit floor
- Float switch settings that let the pump pull in air
- A partly closed discharge valve
Why Does the Impeller Matter So Much in Sewage Pump Clogging?
The impeller is the first part to meet the solids. Its shape decides what passes and what catches.
Different Sewage Conditions Need Different Impeller Designs
Types of sewage vary. Raw sewage, treated effluent and industrial sewage behave differently. So do the impellers built for them.
- Vortex impeller: It sits back from the flow path, so solids pass with little contact. It copes well with stringy material but is less efficient.
- Single vane or two vane impeller: It has a wide channel for large solids and fibers. It is a common choice for raw sewage.
- Open and semi-open impeller: It suits sludge and light solids. Wear widens the gap over time, and efficiency falls.
- Multi-vane closed impeller: It is the most efficient. Its narrow passages suit cleaner liquid, such as screened or treated effluent.
Match the impeller to the worst sewage you expect.
How to Troubleshoot a Submersible Sewage Pump That Keeps Clogging
Safety first. Isolate and lock out the power before you touch the pump. Lift it by its chain or rope, never by the cable. Treat the wet well as a confined space, because gas can build up there.
Check 1: What Is Actually Causing the Blockage?
Pull the pump and look at what is stuck. Rags point to a fiber problem. Hard gritty mass means sediment. A greasy mat means grease. Stones or large items mean solids above the free passage. Take a photo each time.
Check 2: Check the Impeller and Passage
After cleaning, turn the impeller by hand. Look for bent or worn vanes, scoring and extra clearance. Damage like this lets fibers catch and cuts flow, even when the pump looks clean.
Check 3: Compare the Pump With the Actual Sewage
Check the free passage, impeller type and materials against the real sewage. Has the load changed since installation? New users, a new process line or a rainy season can all change it. The sewage changes over time. The pump does not.
Check 4: Review Installation and Operating Conditions
- Is the pump clear of sludge on the pit floor?
- Do the float switch levels stop the pump before it sucks air?
- Is the check valve free, and is the discharge valve fully open?
- Does a three-phase pump turn in the right direction? Wrong rotation cuts flow.
- Is the flow in the discharge line high enough to keep solids moving?
Electrical issues, such as voltage drop, can also show up as weak flow.
Check 5: Review the Pattern of Repeated Failures
Keep a simple log. Note the date, what you found and the hours since the last clean. Do clogs follow rain? Do they come from one pump only? Patterns point to the source, such as one grease-heavy discharge or a surge at peak hours.
How Can You Prevent Repeated Sewage Pump Clogging?
Keep Oversized and Problematic Solids Out of the Pump
Fit a bar screen or trash basket at the inlet and clean it on a routine. Use grease traps where kitchens or food processing feed the sewer. Tell users what not to flush. A screen costs far less than a pulled pump.
Select the Pump and Impeller for the Actual Sewage
Choose the free passage and impeller for the worst solids you expect. The selection section below lists what to check.
Follow Preventive Inspection and Cleaning
Clean the wet well on a schedule so sludge does not pile up, and pull each pump at set intervals to check the seals, oil, cable and impeller. Ask maintenance personnel to log what they find. Overload protection in the starter panel can also warn you before a clog trips the pump, and these habits help extend pump life.
Don’t Treat Every Clog With the Same Fix
Each cause needs its own fix:
- Rags need screens or a better impeller.
- Grease needs source control and cleaning.
- Grit needs better flow velocity and sump cleaning.
- A wrong pump size needs a better match.
Flushing with water or fitting a bigger motor rarely solves it.
When Is It a Pump Problem and When Is It a System Problem?
Use this table to decide where to look first.
| What you see | Likely cause | Where to look |
| Impeller is clean but flow is low | Wrong rotation, worn impeller, blocked check valve, air lock | Motor rotation, impeller clearance, valves |
| Rags on the impeller every few weeks | Impeller not suited to fibers, or no screening | Impeller type, inlet screens |
| Clogs only after rain or at peak use | Load above design | Design flows, solids in storm flow |
| Grease mat in the pit | Grease at the source | Upstream users, grease traps |
| Solids settle in the discharge line | Flow velocity too low | Pipe size, pump duty point |
As a rule, if a pump runs well after cleaning and clogs weeks later, look at the system. If it clogs soon after every clean with the same sewage, look at the pump.
Common Mistakes That Lead to Repeated Clogging
- Clearing the clog and moving on. If you never find the cause, it returns.
- Buying on price and motor size. Free passage and impeller type matter more for sewage.
- Throttling the discharge valve. Lower flow lets solids settle in the line.
- Letting sludge and grease build up in the pit. The pump then pulls it in.
- Ignoring the check valve. A jammed valve causes backflow and extra starts.
- Skipping the log. Without records, you cannot see the pattern.
Choosing a Non-Clog Submersible Sewage Pump
A non-clog pump lowers the risk of blockage, but it does not remove it. Installation type matters too, because a submersible pump works inside the pit, whereas VNC and HNC pumps are installed differently. When you choose a pump, check these points:
- Free passage against the largest solid you expect
- Impeller type for your sewage
- Flow and head at your duty point
- Materials for corrosive or abrasive sewage
- Dual mechanical seals and moisture and temperature sensors
- Fit for your pit or manhole
Why Choose HET Pump’s Non-Clog Submersible Sewage Pump?
Our SEW series is designed to handle sewage containing solids. It has dual mechanical seals and offers different impeller designs, including open, semi-open, closed, vortex, single-vane, two-vane and multi-vane options. Built-in moisture and temperature sensors help monitor the pump’s condition.
The pump can handle solids ranging from 20 to 125 mm. An agitator, cutter or special hydraulic design is also available on request. The casing and motor parts are made of cast iron, while the impeller is available in cast iron or stainless steel. Other material options can be requested. The range offers flow rates up to 2,000 m³/hr, heads up to 150 m and motor ratings from 2 to 250 HP.
For manholes and smaller pits, the MSEW non-clog manhole pump handles solids ranging from 20 to 100 mm and fits sumps as small as 460 mm. Both pump series are used in municipal applications and ETP plants.
Choosing the right pump depends on the type of sewage, solid size, flow rate and required head. Share these details with our team to help identify a suitable option.
Frequently Asked Questions
Why does my sewage pump keep switching on and off?
Frequent starts usually come from a fouled or badly set float switch, or from a leaking check valve that lets water drain back into the pit. A pit that is too small for the inflow can cause it too. If the pump also stops by itself, check whether a partial clog is tripping the overload.
How long does a submersible sewage pump last?
There is no fixed figure, because life depends on the sewage, the running hours, the materials and the maintenance. A pump that is correctly sized, kept clear of rags and grease and serviced at regular intervals can last many years, while a mismatched pump may need repairs within months.
Should I use a grinder pump or a non-clog pump?
A grinder pump cuts solids into a slurry so they can pass through a small-bore pressure line, which is common in small pressure sewer systems. A non-clog pump passes larger solids through a wide impeller channel and suits pump stations and larger pipes. The choice depends on your pipe size and what is in the sewage, and cutters add parts that need servicing.
What other problems affect sewage pumps besides clogging?
The common ones are worn mechanical seals that let water into the motor, overheating from dry running or low voltage, damaged cables, worn impellers, and failed float switches or check valves. Water in the oil chamber or a motor protector that keeps tripping is a sign to pull the pump.
Do I need a standby sewage pump?
For any duty where a failure could cause a backup, yes. Many pump stations use two pumps that alternate, so one keeps running while the other is cleaned or repaired, and the wear is shared between them.
Conclusion
A submersible sewage pump that keeps clogging is telling you something. Find what is stuck, check the impeller and free passage, and compare the pump with the real sewage. Fix the source first. If the pump is the problem, choose a non-clog design that suits your sewage. Then keep a simple inspection routine.
Need help with a pump that keeps clogging? Contact HET Pump with your flow, head and sewage details.